Register for email alerts and news feeds:
This journal | BMJ Group
rss
Archives of Disease in Childhood - Fetal and Neonatal Edition 1998;79:F100-F104; doi:10.1136/fn.79.2.F100
Copyright © 1998 BMJ Publishing Group Ltd & Royal College of Paediatrics and Child Health.
Arch Dis Child Fetal Neonatal Ed 1998;79:F100-F104 ( September )

Randomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease

T F Fok, K Lam, P C Ng, H K So, K L Cheung, W Wong, K W So

Department of Paediatrics, The Chinese University of Hong Kong, The Prince of Wales Hospital, Shatin, Hong Kong, People's Republic of China

Correspondence to: Dr T F Fok.


Accepted 4 February 1998

AIMS---To compare the efficacy of salbutamol delivered by metered dose inhaler (MDI), jet nebuliser, and ultrasonic nebuliser in ventilated infants with chronic lung disease.
METHODS---Twenty preterm ventilated infants with chronic lung disease were enrolled in two studies. In study 1 (n=10), each infant was given 200 µg of salbutamol at 4 hour intervals and in random sequence from a metered dose inhaler-spacer device, a jet nebuliser, and an ultrasonic nebuliser with a small medication cup. The infants were monitored for heart rate, transcutaneous pO2, pCO2, and oxygen saturation, respiratory system resistance and compliance before and after each treatment. Infants in study 2 (n=10) were similarly studied except for the use of a different jet nebuliser.
RESULTS---The mean (SEM) maximum percentage decreases in respiratory system resistance, observed at 30 minutes after aerosol delivery were study 1: MDI: 44.3 (4.3)% ; jet: 32.3 (3.4)% ; ultrasonic: 56.1 (3.2)% ; study 2: MDI: 28.6 (1.0)% ; jet: 16.9 (1.4)% ; ultrasonic: 42.1 (1.6)%. During the first hour after treatment, a significantly faster heart rate and higher transcutaneous pO2 were associated with the use of the ultrasonic nebuliser or MDI than with the jet nebulisers in both studies. The use of the ultrasonic nebuliser but not the other devices also resulted in a lower transcutaneous pCO2 and improved respiratory system compliance in study 2.
CONCLUSIONS---These findings suggest that among the devices tested, the delivery of salbutamol aerosol to the lower respiratory tract was greatest using the ultrasonic nebuliser, and least with the jet nebulisers.

Keywords: aerosol; salbutamol; metered dose inhaler; jet nebuliser; ultrasonic nebuliser


© 1998 by Archives of Disease in Childhood

Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • (2003). Statement on the Care of the Child with Chronic Lung Disease of Infancy and Childhood. Am. J. Respir. Crit. Care Med. 168: 356-396 [Full Text]  
  • Palmer, D., Schurch, S., Belik, J. (2000). Effect of budesonide and salbutamol on surfactant properties. J. Appl. Physiol. 89: 884-890 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Latest from ADC

 

ADC is co-owned by the RCPCH and is the official journal of the European Academy of Paediatrics

BMJ Careers - Latest Paediatrics and Paediatric Surgery Jobs

Paediatrics and Paediatric Surgery Jobs