Register for email alerts and news feeds:
This journal | BMJ Group
rss
Published Online First: 26 November 2007. doi:10.1136/adc.2007.117788
Archives of Disease in Childhood - Fetal and Neonatal Edition 2008;93:F230-F234
Copyright © 2008 BMJ Publishing Group Ltd & Royal College of Paediatrics and Child Health.

ORIGINAL ARTICLES

Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2

Fiona E Wood1,2,3,4, Colin J Morley1,2,3,4, Jennifer A Dawson1,2,3,4, C Omar F Kamlin1,2,3,4, Louise S Owen1,2,3,4, Susan Donath1,2,3,4 and Peter G Davis1,2,3,4

1 Division of Neonatal Services, The Royal Women’s Hospital, Carlton, Victoria 3053, Australia
2 Departments of Obstetric and Gynaecology, University of Melbourne, Victoria 3053, Australia
3 Murdoch Children’s Research Institute, Melbourne Victoria 3052, Australia
4 Department of Paediatrics, University of Melbourne, Victoria 3052, Australia

Correspondence to:
Professor Colin J Morley, Division of Neonatal Services, The Royal Women’s Hospital, 132 Grattan Street, Carlton, Victoria, 3053, Australia; colin.morley{at}rwh.org.au

Background: Techniques of positioning and holding neonatal face masks vary. Studies have shown that leak at the face mask is common and often substantial irrespective of operator experience.

Aims: (1) To identify a technique for face mask placement and hold which will minimise mask leak. (2) To investigate the effect of written instruction and demonstration of the identified technique on mask leak for two round face masks.

Method: Three experienced neonatologists compared methods of placing and holding face masks to minimise the leak for Fisher & Paykel 60 mm and Laerdal size 0/1 masks. 50 clinical staff gave positive pressure ventilation to a modified manikin designed to measure leak at the face mask. They were provided with written instructions on how to position and hold each mask and then received a demonstration. Face mask leak was measured after each teaching intervention.

Results: A technique of positioning and holding the face masks was identified which minimised leak. The mean (SD) mask leaks before instruction, after instruction and after demonstration were 55% (31), 49% (30), 33% (26) for the Laerdal mask and 57% (25), 47% (28), 32% (30) for the Fisher & Paykel mask. There was no significant difference in mask leak between the two masks. Written instruction alone reduced leak by 8.8% (CI 1.4% to 16.2%) for either mask; when combined with a demonstration mask leak was reduced by 24.1% (CI 16.4% to 31.8%).

Conclusion: Written instruction and demonstration of the identified optimal technique resulted in significantly reduced face mask leak.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Morley, C. J, Davis, P. G (2008). Advances in neonatal resuscitation: supporting transition. Arch. Dis. Child. Fetal Neonatal Ed. 93: F334-F336 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Latest from ADC

 

ADC is co-owned by the RCPCH and is the official journal of the European Academy of Paediatrics

BMJ Careers - Latest Paediatrics and Paediatric Surgery Jobs

Paediatrics and Paediatric Surgery Jobs