ORIGINAL ARTICLES

Reducing errors in the management of hyperbilirubinaemia: validating a software application

A Balaguer1,2, R Quiroga-González3, M Camprubí4, M Milá-Farnés2, J Escribano2 and M Girabent-Farrés1

1 Universitat Internacional de Catalunya, Barcelona, Spain
2 Neonatal Unit, Hospital Sant Joan de Reus, Tarragona, Spain
3 Hospital Universitario Central de Asturias, Oviedo, Spain
4 Hospital Universitari Sant Joan de Deu, Barcelona, Spain

Correspondence to:
Albert Balaguer, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain; abalaguer{at}csc.uic.es

Objective: To verify the usefulness and reliability of a software tool we developed to help to apply the American Academy of Pediatrics (AAP) Guidelines 2004 on hyperbilirubinaemia according to the infant’s age in hours and their clinical risk factors.

Design: Randomised, cross-over, controlled trial with 20 simulated clinical cases comparing the "manual" application of the guidelines with our software application.

Participants: Fifteen doctors (eight final-year residents and seven consultants) from two hospitals in Spain.

Main outcome measures: Major errors (defined a priori as any deviation from the AAP guidelines that involve a risk of morbidity or mortality for the patient), minor errors (those that cause discomfort and/or, in extremely rare cases, morbidity) and time spent.

Results: Fifteen doctors each managed 20 simulated cases, half by using the guidelines alone and half using the software tool. Without the software application, 42 "minor" errors were made. With it, only 25 errors were made. "Major" errors also decreased from 10 to 2 with the software. As a group, the residents benefited most; they made an average of 1.8 errors fewer per 10 cases. Use of the software reduced the time taken by the residents to resolve the cases, although the mean reduction in time was not significant for the group of consultants.

Conclusions: The use of simulated clinical cases revealed many errors in the routine management of hyperbilirubinaemia. The software helped clinicians make fewer errors and saved time for residents, but not consultants.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Kemp, C. (2009). Software reduces errors in managing hyperbilirubinemia. AAP News 30: 2-2 [Full Text]  

eLetters:

Read all eLetters

Design of a software application for the screening of babies with prolonged neonatal jaundice
Michael O. Ogundele
Fetal Neonatal Ed. Online, 5 Jan 2009 [Full text]

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Latest from ADC

 

ADC is co-owned by the RCPCH and is the official journal of the European Academy of Paediatrics

BMJ Careers - Latest Paediatrics and Paediatric Surgery Jobs

Paediatrics and Paediatric Surgery Jobs