Arch Dis Child Fetal Neonatal Ed 2001;84:F129-F130 doi:10.1136/fn.84.2.F129
  • Original article

Positioning long lines: contrast versus plain radiography

  1. A Reece,
  2. T Ubhi,
  3. A R Craig,
  4. S J Newell
  1. Neonatal Unit, St James's University Hospital, Leeds LS9 7TF, UK
  1. Dr Newellnewells{at}sjuhnnu.demon.co.uk
  • Accepted 12 October 2000

Abstract

AIM To assess the value of contrast versus plain radiography in determining radio-opaque long line tip position in neonates.

METHODS In a prospective study, plain radiography was performed after insertion of radio-opaque long lines. If the line tip was not visible on the plain film, a second film with contrast was obtained in an attempt to visualise the tip.

RESULTS Sixty eight lines were inserted during the study period, 62 of which were included in the study. In 31, a second radiographic examination with contrast was necessary to determine position of the tip. In 29 of these, the line tip was clearly visualised with contrast. On two occasions, the line tip could not be seen because the contrast had filled the vein and obscured the tip from view. Eight of the lines that required a second radiograph with contrast were repositioned.

CONCLUSION Intravenous contrast should be routinely used in the assessment of long line position in the neonate.

Footnotes

    Responses to this article

    Register for free content

    The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.