rss
Arch Dis Child Fetal Neonatal Ed 2004;89:F360-F363 doi:10.1136/adc.2002.019448
  • Original article

The neorule: a new instrument to measure linear growth in preterm infants

  1. C J Lawn1,
  2. R J Chavasse1,2,
  3. K A Booth1,
  4. M Angeles2,
  5. F J Weir1
  1. 1Trevor Mann Baby Unit, Royal Sussex County Hospital, Brighton, UK
  2. 2Department of Neonatology, Royal Women’s Hospital, Carlton, Victoria, Australia
  1. Correspondence to:
    Dr Lawn
    Trevor Mann Baby Unit, Royal Sussex County Hospital, Eastern Road, Brighton BN2 5BE, UK; cassie.lawn{at}bsuh.nhs.uk
  • Accepted 15 September 2003

Abstract

Objectives: To compare measurements of crown-heel length (CHL) made with the neorule with CHL measurements made with a stadiometer in term infants. To examine safety and reproducibility of CHL measurements in infants < 32 weeks gestational age (GA) using the neorule.

Methods: Three measurements of CHL were made by three teams during the first 2 days of life in healthy term infants. One team used the stadiometer and two the neorule. Two different teams made three measurements of CHL on four occasions at two week intervals in infants less than 32 weeks GA. Infants were continuously monitored, and any adverse event was recorded.

Results: Fifty term infants were studied, median (range) birth weight 3440 (2020–5010) g. The mean (SD, 95% confidence interval) difference between values obtained with the stadiometer and neorule was 0.08 (6.22, −1.69 to +1.85) mm and between the two neorule teams was 0.8 (4.48, −0.47 to +2.08) mm. Twenty preterm infants were studied, GA median (range) 29 (25+0–31+6) weeks, median (range) CHL 397 (339–475) mm. There were no adverse events. The difference (SD, 95%CI) between teams in the mean CHL measurement was 0.18 (4.79, −1.02 to +1.38) mm, with interobserver limit of agreement −9.2 to +9.6 mm and coefficient of variation 1.2%. There were no significant differences between measurements made by single observers; the F ratio was 0.449 (df  =  61, p  =  0.6).

Conclusion: The neorule is a safe and accurate way to measure CHL in newborn infants.

Footnotes

    Responses to this article

    Register for free content

    The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.