Arch Dis Child Fetal Neonatal Ed 2005;90:F419-F422 doi:10.1136/adc.2003.027698
  • Original article

Severity of the ductal shunt: a comparison of different markers

  1. M El Hajjar1,
  2. G Vaksmann2,
  3. T Rakza1,
  4. G Kongolo3,
  5. L Storme1
  1. 1Clinique de Médecine Néonatale, Hôpital Jeanne de Flandre, CHRU de Lille, Lille, France
  2. 2Service de Cardiologie Pédiatrique, CHRU de Lille
  3. 3Service de Réanimation Pédiatrique, CHRU d’Amiens, Amiens, France
  1. Correspondence to:
    Dr Storme
    Service de Médecine Néonatale, Hôpital Jeanne de Flandre, CHRU de Lille, Lille cédex 59037, France; lstormechru-lille.fr
  • Accepted 16 March 2005

Abstract

Background: When the ductus arteriosus (DA) is patent, the ductal shunt is proportional to the ratio of left ventricular output (LVO) to systemic blood flow. Systemic blood flow can be estimated by measuring flow in the superior vena cava (SVC).

Objective: To re-evaluate the accuracy of standard echocardiographic markers of patent ductus arteriosus (PDA) using LVO/SVC flow ratio.

Methods: Prospective study. Preterm infants of 24–30 weeks gestational age and postnatal age less than 48 hours. The following echocardiographic criteria were measured: left atrial to aortic root ratio (LA/Ao); DA diameter by B mode and colour Doppler; mean and end diastolic flow velocity of the left pulmonary artery (LPA); LVO; SVC flow.

Results: Twenty three preterm infants were enrolled (median gestational age 28 weeks (range 24–30), median birth weight 840 g (500–1440)). The DA was closed in eight (mean (SD) LVO/SVC 2.4 (0.3)) and open in 15 (mean (SD) LVO/SVC 4.5 (0.6)). An LA/Ao ratio ≥1.4, a DA diameter ≥1.4 mm/kg, and a mean and end diastolic flow velocity of LPA respectively ≥0.42 and ≥0.20 m/s identified an LVO/SVC ≥4 with a sensitivity and a specificity above 90%.

Conclusion: This study indicates that LA/Ao ratio, DA diameter, and mean and end diastolic flow velocity of the LPA are accurate markers of PDA. These standard echocardiographic variables are easy to measure and need less skill and resources than direct measurements of ductal shunt.

Footnotes

  • Competing interests: none declared

Latest from Education & Practice

Latest from Education & Practice

Register for free content

Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of ADC Fetal & Neonatal.
View free sample issue >>

Free archive
The full back archive is now available for ADC Fetal & Neonatal. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

  • Paediatrics and Paediatric Surgery Jobs

    Paediatrics and Paediatric Surgery Jobs