Arch Dis Child Fetal Neonatal Ed 2009;94:F183-F187 doi:10.1136/adc.2007.132019
  • Original article

Evaluation of portal venous gas detected by ultrasound examination for diagnosis of necrotising enterocolitis

  1. M Dördelmann1,
  2. G A Rau1,
  3. D Bartels2,
  4. M Linke1,
  5. N Derichs1,
  6. C Behrens1,
  7. B Bohnhorst1
  1. 1
    Department of Pediatric Pulmonology and Neonatology, Hannover Medical School, Hannover, Germany
  2. 2
    Department of Epidemiology, Hannover Medical School, Hannover, Germany
  1. Bettina Bohnhorst, Department of Pediatric Pulmonology and Neonatology, Hannover Medical School, Carl-Neuberg-Straße 1, D-30625 Hannover; bohnhorst.bettina{at}mh-hannover.de
  • Accepted 22 August 2008
  • Published Online First 11 September 2008

Abstract

Background: Early diagnosis of necrotising enterocolitis (NEC) is difficult but essential for timely therapy. The diagnostic hallmarks and specific radiological signs for NEC are pneumatosis intestinalis (PI) and portal venous gas (PVG), but PVG in abdominal ultrasound (PVG-US) has been proposed as an effective tool in the diagnosis of NEC as well.

Objective: To prospectively assess the value of PVG-US for the diagnosis of NEC.

Methods: The study screened 352 neonates for PVG-US (n = 796 routine examinations) and performed 48 additional screenings in 34/352 neonates with suspected (stage I, n = 28) or definite NEC (stage ≥II, n = 20). Sensitivity and specificity of PVG-US for detection of NEC were computed by using NEC stage ≥II as the reference standard.

Results: PVG-US was only present in cases of suspected or definite NEC. The study observed PVG-US in 4/28 NEC stage I and in 9/20 NEC stage ≥II episodes corresponding to a 86% specificity and a 45% sensitivity for diagnosis of NEC stage ≥II. However, 7/20 patients with NEC stage ≥II showed intraoperative findings other than NEC and another 3/20 infants presented with radiologically unspecific intestinal dilatation. None of these 10 infants had detectable PVG-US. Thus, with application of specific radiological signs the sensitivity of PVG-US for diagnosis of NEC stage ≥II increased to 90%.

Conclusion: Screening for PVG-US is a useful, easy and quick bedside test with a high specificity for NEC. Moreover, these results question the value of the Walsh criteria in the diagnosis of NEC.

Footnotes

  • Competing interests: None.

  • Ethics approval: This prospective observational study was performed in a tertiary level university hospital and was approved by the institution’s ethics advisory committee.

  • Patient consent: Parental consent obtained.

This Article

  1. All Versions of this Article:
    1. adc.2007.132019v1
    2. 94/3/F183 most recent

Services

  1. Request permissions

Responses

  1. Submit a response
  2. No responses published

Social bookmarking

Latest from Education & Practice

Latest from Education & Practice

Register for free content

Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of ADC Fetal & Neonatal.
View free sample issue >>

Free archive
The full back archive is now available for ADC Fetal & Neonatal. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

  • Paediatrics and Paediatric Surgery Jobs

    Paediatrics and Paediatric Surgery Jobs