Arch Dis Child Fetal Neonatal Ed doi:10.1136/adc.2006.107656

The accuracy of pulse oximetry in screening for congenital heart disease in asymptomatic newborns: A systematic review

  1. Shakila Thangaratinam (s.thangaratinam{at}bham.ac.uk)
  1. Birmingham Women's Hospital, United Kingdom
    1. Jane Daniels
    1. Birmingham Women's Hospital, United Kingdom
      1. Andrew K Ewer
      1. University of Birmingham, United Kingdom
        1. Javier Zamora
        1. University Complutense of Madrid, Spain
          1. Khalid S Khan
          1. Birmingham Women's Hospital, United Kingdom
            • Published Online First 7 March 2007

            Abstract

            Objective To evaluate the accuracy of pulse oximetry as a screening tool for congenital heart disease in asymptomatic newborns.

            Design, data sources, and methods: Systematic review of relevant studies identified through Medline, Embase, PsycINFO, Cochrane Library. SCISEARCH, conference papers, and bibliographies of retrieved primary and review articles. Two reviewers independently extracted data on study characteristics, quality, and results to construct 2x 2 tables with congenital heart disease as the reference standard. We used a random- effects bivariate model to meta-analyse estimates of sensitivity and specificity. Logit pairs of sensitivity and specificity of each study were analysed in a single model, accounting for their correlation due to differences in threshold between studies.

            Results: We extracted 8 studies with a total of 35,960 newborns. Pulse oximetry was performed on asymptomatic newborns in all studies, with three studies excluding newborns with an antenatal diagnosis of congenital heart disease. The studies measured either functional or fractional oxygen saturation by pulse oximetry with oxygen saturation below 95% considered as the cut off level in most studies. Based on 8 studies, the summary estimates of sensitivity and specificity were 63% (95% CI, 39% to 83%) and 99.8% (95% CI, 99% to 100%) respectively, yielding a false positive rate of 0.2% (95% CI, 0% to 1%).

            Conclusion: Pulse oximetry has been shown to be highly specific tool with very low false positive rates to detect congenital heart disease. Further large well conducted prospective studies are needed to assess its sensitivity with higher precision.

            Latest from Education & Practice

            Latest from Education & Practice

            Register for free content

            Free sample
            This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of ADC Fetal & Neonatal.
            View free sample issue >>

            Free archive
            The full back archive is now available for ADC Fetal & Neonatal. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
            Register to access the free archive >>

            Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

          1. Paediatrics and Paediatric Surgery Jobs

            Paediatrics and Paediatric Surgery Jobs