rss
Arch Dis Child Fetal Neonatal Ed doi:10.1136/adc.2007.132282

Does monitoring method influence stability of oxygenation in preterm infants? A randomised crossover study of saturation versus transcutaneous monitoring.

  1. David Quine (drdquine{at}toucansurf.com)
  1. Neonatal Unit, Simpson Centre for Reproductive Health, Edinburgh, United Kingdom
    1. Ben J Stenson (ben.stenson{at}luht.scot.nhs.uk)
    1. Simpson Centre for Reproductive Health, Edinburgh, United Kingdom
      • Published Online First 19 February 2008

      Abstract

      Introduction: Hyperoxia and variable oxygenation are associated with morbidity in preterm infants. The optimal range of oxygen tensions is not known. We aimed to determine whether care based on transcutaneous oxygen tension (TcPO2) or saturation (SpO2) monitoring is associated with less time spent with high oxygen tension and less variability of oxygenation.

      Methods: SpO2 and TcPO2 were measured simultaneously during two 3-hour study periods allocated in random order. During one period supplemental oxygen was adjusted according to TcPO2 (target range 6.0-9.0kPa) and during the other according to SpO2 (target range 86-94%). During each period readings from the second monitor were not displayed. Both TcPO2 and SpO2 were downloaded every second. For each period the mean level and the variability (standard deviation) of SpO2 and TcPO2 and the percentage of time spent above and below target range were calculated and compared.

      Results: Nineteen infants, 13 ventilated and 6 on CPAP, were studied at mean corrected gestational age of 27.2 weeks and mean postnatal age of 6.8 days. Their mean FiO2 at the start of the study was 0.34. Care based on SpO2 monitoring was associated with more time spent with high oxygen tension (median increase 2.62%, p=0.01), more time with low oxygen tension (median increase 17.41%, p=0.01), more variability in oxygen tension (median increase 0.28kPa, p=0.02) and more variability in oxygen saturation (median increase 0.82%, p=0.01) than care based on TcPO2 monitoring.

      Conclusion: Within the target ranges studied SpO2 monitoring was associated with significantly more variable oxygenation than TcPO2 monitoring.

      This Article

      1. All Versions of this Article:
        1. adc.2007.132282v1
        2. 93/5/F347 most recent

      Services

      1. Request permissions

      Responses

      1. Submit a response
      2. No responses published

      Social bookmarking

      Latest from Education & Practice

      Latest from Education & Practice

      Register for free content

      Free sample
      This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of ADC Fetal & Neonatal.
      View free sample issue >>

      Free archive
      The full back archive is now available for ADC Fetal & Neonatal. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
      Register to access the free archive >>

      Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

    1. Paediatrics and Paediatric Surgery Jobs

      Paediatrics and Paediatric Surgery Jobs