rss
Arch Dis Child Fetal Neonatal Ed doi:10.1136/adc.2007.133157

Reducing errors in the management of hyperbilirubinemia: validating a software application.

  1. Albert Balaguer (albert_balaguer{at}yahoo.es)
  1. Hospital St. Joan Reus. Tarragona. URV and Universitat Internacional de Catalunya. Barcelona., Spain
    1. Rocio Quiroga-González (roquiroga_salinas{at}hotmail.com)
    1. Hospital Universitario Central de Asturias. Oviedo., Spain
      1. Marta Camprubí Camprubí (mcamprubic{at}hsjdbcn.org)
      1. Hospital Universitari Sant Joan de Déu, Barcelona,, Spain
        1. María Milá-Farnés (maria_mila{at}hotmail.com)
        1. Hospital Universitari Sant Joan de Reus., Spain
          1. Joaquin Escribano (jescribano{at}grupsagessa.com)
          1. Hospital Universitari St. Joan Reus. Universitat Rovira i Virgili. Reus-Tarragona., Spain
            1. Montserrat Girabent Farrés (montserratgirabent{at}gmail.com)
            1. Universitat Internacional de Catalunya. Barcelona., Spain
              • Published Online First 18 June 2008

              Abstract

              Objective: To verify the usefulness and reliability of a software tool we developed to help to apply the American Academy of Pediatrics Guidelines 2004 on hyperbilirubinemia according to the infant's age in hours and their clinical risk factors.

              Design: Randomised cross-over controlled trial with 20 simulated clinical cases comparing the "manual"application of the guidelines with our software application.

              Participants: Fifteen doctors (eight final-year residents and seven consultants) from two hospitals in Spain.

              Main outcome measures: Major errors (defined a priori as any deviation from the AAP guideline that involves a risk of morbidity or mortality for the patient), minor errors (those that cause discomfort and/or, in extremely rare cases, morbidity) and time spent.

              Results: Fifteen doctors each managed 20 simulated cases, half by using the guideleines alone and half using the software tool. Without the software application, 42 "minor" errors were made. With it, only 25 errors were made. "Major" errors also decreased from 10 to 2 with the software. As a group, the residents benefited most: they made an average of 1.8 errors fewer per ten cases. Use of the software reduced the time taken by the residents to resolve the cases, although the mean reduction in time was not significant for the group of consultants.

              Conclusions: The use of simulated clinical cases revealed many errors in the routine management of hyperbilirubinemia. The software helped clinicians make fewer errors and saved time for residents, but not consultants.

              Latest from Education & Practice

              Latest from Education & Practice

              Register for free content

              Free sample
              This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of ADC Fetal & Neonatal.
              View free sample issue >>

              Free archive
              The full back archive is now available for ADC Fetal & Neonatal. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
              Register to access the free archive >>

              Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

            1. Paediatrics and Paediatric Surgery Jobs

              Paediatrics and Paediatric Surgery Jobs