rss
Arch Dis Child Fetal Neonatal Ed doi:10.1136/adc.2007.132019

Evaluation of portal venous gas detected by ultrasound examination for diagnosis of NEC

  1. Michael Dördelmann (doerdelmann.michael{at}mh-hannover.de)
  1. Medical School Hannover, Germany
    1. Gunnar Rau (rau.gunnar{at}mh-hannover.de)
    1. Medical School Hannover, Germany
      1. Dorothee Bartels (bartels.dorothee{at}mh-hannover.de)
      1. Medical School Hannover, Germany
        1. Marion Linke (linke.marion{at}mh-hannover.de)
        1. Medical School Hannover, Germany
          1. Nico Derichs (derichs.nico{at}mh-hannover.de)
          1. Medical School Hannover, Germany
            1. Clemens Behrens (behrens.clemens{at}mh-hannover.de)
            1. Medical School Hannover, Germany
              1. Bettina Bohnhorst (bohnhorst.bettina{at}mh-hannover.de)
              1. Medical School Hannover, Germany
                • Published Online First 11 September 2008

                Abstract

                Background: Early diagnosis of necrotizing enterocolitis (NEC) is difficult but essential for timely therapy. The diagnostic hallmarks and specific radiologic signs for NEC are pneumatosis intestinalis (PI) and portal venous gas (PVG), but PVG in abdominal ultrasound (PVG-US) has been proposed as an effective tool in the diagnosis of NEC as well.

                Objective: We prospectively assessed the value of PVG-US for the diagnosis of NEC.

                Methods: We screened 352 neonates for PVG-US (n = 796 routine examinations) and performed 48 additional screenings in 34/352 neonates with suspected (I°, n = 28) or definite NEC (≥ II°, n = 20) as defined by Walsh and Kliegman. Sensitivity and specificity of PVG-US for detection of NEC were computed by using NEC ≥ II° as the reference standard.

                Results: PVG-US was only present in cases of suspected or definite NEC. We observed PVG-US in 4/28 NEC I° and in 9/20 NEC ≥ II° episodes corresponding to a 86% specificity and a 45% sensitivity for diagnosis of NEC ≥ II°. However, 7/20 patients with NEC ≥ II° showed intraoperative findings other than NEC and another 3/20 infants presented with radiologically unspecific intestinal dilatation. None of these 10 infants had PVG-US detectable. Thus, with application of specific radiologic signs the sensitivity of PVG-US for diagnosis of NEC ≥ II° increased to 90%.

                Conclusion: Screening for PVG-US is a useful, easily and quickly performed bedside test with a high specifity for NEC. Moreover, our results question the value of the Walsh criteria in the diagnosis of NEC.

                This Article

                1. All Versions of this Article:
                  1. adc.2007.132019v1
                  2. 94/3/F183 most recent

                Services

                1. Request permissions

                Responses

                1. Submit a response
                2. No responses published

                Social bookmarking

                Latest from Education & Practice

                Latest from Education & Practice

                Register for free content

                Free sample
                This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of ADC Fetal & Neonatal.
                View free sample issue >>

                Free archive
                The full back archive is now available for ADC Fetal & Neonatal. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
                Register to access the free archive >>

                Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

              1. Paediatrics and Paediatric Surgery Jobs

                Paediatrics and Paediatric Surgery Jobs